9EM5
OPR3 variant Y364P in its monomeric form
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-02-08 |
Detector | DECTRIS EIGER2 X 9M |
Wavelength(s) | 0.87 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 44.338, 89.941, 51.284 |
Unit cell angles | 90.00, 105.63, 90.00 |
Refinement procedure
Resolution | 49.390 - 1.600 |
R-factor | 0.185 |
Rwork | 0.184 |
R-free | 0.20750 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.394 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.21_5207) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.390 | 1.600 |
High resolution limit [Å] | 1.570 | 1.570 |
Rpim | 0.060 | 1.260 |
Number of reflections | 54069 | 14664 |
<I/σ(I)> | 5.8 | |
Completeness [%] | 98.8 | |
Redundancy | 3 | |
CC(1/2) | 0.990 | 0.350 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M Tris-HCl (7.5), 50 mM sodium tartrate, 8-16% PEG8000 |