Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-E |
| Synchrotron site | APS |
| Beamline | 24-ID-E |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-10-26 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 38.858, 57.467, 124.908 |
| Unit cell angles | 90.00, 94.24, 90.00 |
Refinement procedure
| Resolution | 42.240 - 1.800 |
| R-factor | 0.1943 |
| Rwork | 0.192 |
| R-free | 0.23360 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.591 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.160 | |
| Number of reflections | 85134 | 4320 |
| <I/σ(I)> | 1.1 | |
| Completeness [%] | 95.1 | |
| Redundancy | 3.5 | |
| CC(1/2) | 0.900 | 0.450 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 295 | 100 mM Hepes pH 6.5 and 20% PEG 6000 |