Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9DPN

BMP-9 Wild-Type Dimer Without Radiation Damage in Neutral pH

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-18
DetectorDECTRIS EIGER X 16M
Wavelength(s)1
Spacegroup nameI 41 2 2
Unit cell lengths71.203, 71.203, 146.541
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.500 - 2.240
R-factor0.1958
Rwork0.195
R-free0.20610
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle0.678
Data reduction softwareiMOSFLM
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.5002.310
High resolution limit [Å]2.2402.240
Rmerge0.1570.841
Rmeas0.1991.078
Rpim0.1200.663
Number of reflections8929800
<I/σ(I)>4.31.6
Completeness [%]95.996.7
Redundancy3.23.3
CC(1/2)0.9700.471
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5289.151M NaCl, 17% Glycerol, 0.1 M HEPEs pH 7.5

239492