Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.1 |
| Synchrotron site | ALS |
| Beamline | 8.2.1 |
| Temperature [K] | 103 |
| Detector technology | PIXEL |
| Collection date | 2017-08-18 |
| Detector | DECTRIS PILATUS 300K |
| Wavelength(s) | 1.0 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 76.760, 100.760, 126.490 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 78.810 - 2.810 |
| R-factor | 0.2486 |
| Rwork | 0.247 |
| R-free | 0.27600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.586 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 79.000 | 2.900 |
| High resolution limit [Å] | 2.750 | 2.750 |
| Rmerge | 0.083 | 3.469 |
| Rpim | 0.055 | 2.272 |
| Number of reflections | 12960 | 1911 |
| <I/σ(I)> | 5.5 | 1 |
| Completeness [%] | 98.6 | |
| Redundancy | 3 | |
| CC(1/2) | 0.995 | 0.370 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | PEG 3350, taximate |