Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.2 |
| Synchrotron site | ALS |
| Beamline | 8.2.2 |
| Temperature [K] | 103 |
| Detector technology | PIXEL |
| Collection date | 2017-07-18 |
| Detector | DECTRIS PILATUS 300K |
| Wavelength(s) | 1.0 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 76.020, 101.310, 124.750 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 64.920 - 2.550 |
| R-factor | 0.2339 |
| Rwork | 0.232 |
| R-free | 0.28140 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.663 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 78.640 | 2.690 |
| High resolution limit [Å] | 2.550 | 2.550 |
| Rmerge | 0.070 | 1.596 |
| Rpim | 0.030 | 0.732 |
| Number of reflections | 16009 | 2312 |
| <I/σ(I)> | 11 | 1 |
| Completeness [%] | 99.6 | |
| Redundancy | 5.5 | |
| CC(1/2) | 0.999 | 0.494 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | PEG3350, taximate |