9AVF
CCHFV GP38-GnH-DS heterodimer
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS-II BEAMLINE 19-ID |
| Synchrotron site | NSLS-II |
| Beamline | 19-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-17 |
| Detector | DECTRIS EIGER2 XE 9M |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 63.809, 87.010, 128.759 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 51.750 - 2.500 |
| R-factor | 0.1987 |
| Rwork | 0.197 |
| R-free | 0.23740 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.836 |
| Data reduction software | MOSFLM |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21rc1_5127) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 51.750 | 2.590 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Number of reflections | 25418 | 2446 |
| <I/σ(I)> | 10.4 | 1.8 |
| Completeness [%] | 99.6 | |
| Redundancy | 6.5 | |
| CC(1/2) | 0.992 | 0.546 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8 | 295.15 | 8% (v/v) TacsimateTM pH 8.0, 20% (v/v) PEG 3,350 |