Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL10U2 |
| Synchrotron site | SSRF |
| Beamline | BL10U2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-01-05 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9792 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 158.423, 168.696, 190.683 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 126.350 - 2.770 |
| R-factor | 0.2076 |
| Rwork | 0.207 |
| R-free | 0.24190 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.860 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 126.350 | 2.870 |
| High resolution limit [Å] | 2.770 | 2.770 |
| Rmerge | 0.085 | 0.681 |
| Number of reflections | 99576 | 899 |
| <I/σ(I)> | 7.94 | |
| Completeness [%] | 76.7 | |
| Redundancy | 2 | |
| CC(1/2) | 0.989 | 0.291 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291 | 8% Tacsimate pH6.0+20% PEG 3350 |