8YQC
Galectin-10 C29AC57A
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-30 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97853 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 48.824, 48.824, 261.403 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 19.600 - 1.920 |
| R-factor | 0.2071 |
| Rwork | 0.204 |
| R-free | 0.23810 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.257 |
| Refinement software | PHENIX ((1.18.2_3874: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.600 | 1.970 |
| High resolution limit [Å] | 1.920 | 1.920 |
| Rmerge | 0.106 | 0.778 |
| Number of reflections | 14988 | 995 |
| <I/σ(I)> | 18.4 | |
| Completeness [%] | 98.2 | |
| Redundancy | 16.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | PEG |