8WZ0
SARS-CoV-2 3CLpro bound to covalent inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID09 |
Synchrotron site | ESRF |
Beamline | ID09 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-06-23 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.987 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 45.540, 52.940, 113.960 |
Unit cell angles | 90.00, 100.72, 90.00 |
Refinement procedure
Resolution | 47.910 - 2.450 |
R-factor | 0.25377 |
Rwork | 0.251 |
R-free | 0.29942 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 1.266 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.910 | 2.550 |
High resolution limit [Å] | 2.450 | 2.450 |
Rmerge | 0.151 | 0.047 |
Number of reflections | 19865 | 445 |
<I/σ(I)> | 8.6 | |
Completeness [%] | 99.9 | |
Redundancy | 6.8 | |
CC(1/2) | 0.997 | 0.999 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 0.2M sodium fluoride, 20% PEG 3350 |