Thermus thermophilus initiation complex in the half-translocated state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyCCD
Collection date2012-12-09
DetectorADSC QUANTUM 315r
Wavelength(s)0.97901
Spacegroup nameC 1 2 1
Unit cell lengths183.397, 103.796, 295.035
Unit cell angles90.00, 99.19, 90.00
Refinement procedure
Resolution39.883 - 2.512
R-factor0.1889
Rwork0.187
R-free0.22610
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.012
RMSD bond angle1.036
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.12_2829: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0002.540
High resolution limit [Å]2.5002.500
Rmerge0.1770.843
Number of reflections13368491336849
<I/σ(I)>11.6992
Completeness [%]100.0
Redundancy7.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2950.05M Magnesium chloride, 0.2M Potassium chloride, 0.1M Tris-HCl pH8.0, 10% PEG 4000