8W0T
Human LCAD
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-002 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2004-01-17 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 101.143, 102.052, 173.594 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.130 - 2.500 |
| R-factor | 0.2 |
| Rwork | 0.200 |
| R-free | 0.26200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.400 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | CNS (1.3) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.590 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.281 | |
| Number of reflections | 52001 | 2227 |
| <I/σ(I)> | 15.5 | |
| Completeness [%] | 83.0 | 36 |
| Redundancy | 3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.2 | 291 | TrisHCl, PEG5000MME, NaCl, MgCl2 |