8VY4
Engineering a Tumor-Selective Prodrug T Cell Engager Bispecific Antibody for Safer Immunotherapy
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 31-ID |
| Synchrotron site | APS |
| Beamline | 31-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2018-06-27 |
| Detector | RAYONIX MX225-HS |
| Wavelength(s) | 0.9793 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 48.733, 72.725, 126.695 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.950 - 1.700 |
| R-factor | 0.1814 |
| Rwork | 0.179 |
| R-free | 0.22760 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.847 |
| Data reduction software | XDS |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21rc1_5049) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 36.400 | 1.790 |
| High resolution limit [Å] | 1.700 | 1.700 |
| Rmerge | 0.132 | 0.637 |
| Number of reflections | 50296 | 7290 |
| <I/σ(I)> | 13.2 | |
| Completeness [%] | 99.9 | 99.9 |
| Redundancy | 7.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 294 | 100 mM Bis-Tris pH 6.5 and 20% Polyethylene glycol monomethyl ether 5000 |