Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.2 |
| Synchrotron site | ALS |
| Beamline | 5.0.2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-05-11 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 1.000 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 37.261, 184.761, 108.100 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.190 - 3.100 |
| R-factor | 0.184 |
| Rwork | 0.187 |
| R-free | 0.21200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.636 |
| Data reduction software | xia2 (3.8.6) |
| Data scaling software | DIALS (3.8) |
| Phasing software | PHASER (2.8.3) |
| Refinement software | PHENIX (1.21rc1_5156) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.200 | 3.340 |
| High resolution limit [Å] | 3.100 | 3.100 |
| Number of reflections | 7021 | 1338 |
| <I/σ(I)> | 13.6 | |
| Completeness [%] | 98.1 | |
| Redundancy | 13.1 | |
| CC(1/2) | 0.907 | 0.405 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 294 | HEPES, polyethylene glycol 400, NDSB-195, ammonium acetate. |