Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.2 |
Synchrotron site | ALS |
Beamline | 5.0.2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-05-11 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 37.254, 184.109, 108.562 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.000 - 3.100 |
R-factor | 0.2125 |
Rwork | 0.214 |
R-free | 0.26000 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.498 |
Data reduction software | xia2 (3.8.6) |
Data scaling software | DIALS (3.8) |
Phasing software | PHASER (2.8.3) |
Refinement software | PHENIX (1.21rc1_5156) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.000 | 3.340 |
High resolution limit [Å] | 3.100 | 3.100 |
Number of reflections | 7028 | 1364 |
<I/σ(I)> | 11.4 | |
Completeness [%] | 98.2 | |
Redundancy | 6.2 | |
CC(1/2) | 0.960 | 0.451 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 294 | HEPES, polyethylene glycol 400, 1,4-dioxane, ammonium acetate. |