Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-03-13 |
Detector | DECTRIS EIGER2 XE 16M |
Wavelength(s) | 1.000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 85.494, 109.160, 127.764 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 36.015 - 2.550 |
Rwork | 0.222 |
R-free | 0.25960 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8epu |
RMSD bond length | 0.004 |
RMSD bond angle | 1.137 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0419) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.590 |
High resolution limit [Å] | 2.500 | 2.550 |
Rmerge | 0.090 | 0.623 |
Rmeas | 0.097 | 0.676 |
Rpim | 0.036 | 0.258 |
Number of reflections | 20197 | 1005 |
<I/σ(I)> | 24.3 | 2.3 |
Completeness [%] | 99.9 | 99.3 |
Redundancy | 7.2 | 6.2 |
CC(1/2) | 0.996 | 0.811 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 1.5 M sodium malonate |