8VPD
UIC-11-BIF extension of UIC-1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-09-24 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.688839 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 38.485, 8.794, 31.786 |
| Unit cell angles | 90.00, 113.90, 90.00 |
Refinement procedure
| Resolution | 14.530 - 1.200 |
| R-factor | 0.21 |
| Rwork | 0.208 |
| R-free | 0.23200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.815 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 14.530 | 1.243 |
| High resolution limit [Å] | 1.200 | 1.200 |
| Number of reflections | 3163 | 276 |
| <I/σ(I)> | 4.26 | |
| Completeness [%] | 95.6 | |
| Redundancy | 5.7 | |
| CC(1/2) | 0.984 | 0.782 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | SLOW COOLING | 298 | acetonitrile, water |