Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 101 |
Detector technology | PIXEL |
Collection date | 2016-11-16 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.5416 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 56.960, 41.036, 66.224 |
Unit cell angles | 90.00, 106.55, 90.00 |
Refinement procedure
Resolution | 36.560 - 1.490 |
R-factor | 0.1342 |
Rwork | 0.132 |
R-free | 0.17880 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.013 |
RMSD bond angle | 1.409 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | HKL-3000 |
Refinement software | PHENIX (1.21rc1_5156) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 36.560 | 1.520 |
High resolution limit [Å] | 1.490 | 1.490 |
Rmerge | 0.099 | 0.099 |
Number of reflections | 48409 | 2488 |
<I/σ(I)> | 52.7 | |
Completeness [%] | 99.0 | |
Redundancy | 9.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291.15 | 18% POLYETHYLENE GLYCOL 4000, 50 mM SODIUM ACETATE, 0.1M HEPES, 0.1M LITHIUM SULFATE, |