8V7I
Human DNA polymerase eta-DNA-araC-ended primer ternary complex:reaction with 1 mM Mg2+ for 1800s
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-F |
| Synchrotron site | APS |
| Beamline | 21-ID-F |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2022-09-21 |
| Detector | MAR scanner 300 mm plate |
| Wavelength(s) | 0.9786 |
| Spacegroup name | P 61 |
| Unit cell lengths | 98.547, 98.547, 81.894 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 42.670 - 1.720 |
| R-factor | 0.2134 |
| Rwork | 0.212 |
| R-free | 0.23280 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.175 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 42.672 | 42.672 | 1.820 |
| High resolution limit [Å] | 1.720 | 5.110 | 1.720 |
| Rmerge | 0.056 | 0.022 | 0.714 |
| Rmeas | 0.061 | 0.024 | 0.783 |
| Number of reflections | 47892 | 3567 | 15111 |
| <I/σ(I)> | 20.46 | ||
| Completeness [%] | 98.8 | ||
| Redundancy | 11.5 | ||
| CC(1/2) | 0.999 | 0.999 | 0.773 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | PEG 2000MME, 0.1 M MES |