8TYH

Plasmodium vivax PMX

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2021-10-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 63
Unit cell lengths136.299, 136.299, 45.946
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution42.820 - 1.830
R-factor0.2292
Rwork0.228
R-free0.25090
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.019
RMSD bond angle0.864
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.6101.870
High resolution limit [Å]1.8301.830
Rmerge1.485
Rpim0.471
Number of reflections433432639
<I/σ(I)>16.11.8
Completeness [%]100.0100
Redundancy10.3
CC(1/2)0.9990.712
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP42930.1M SPG 25% (w/v) PEG 1500 30% (v/v) (+/-)-2-Methyl-2,4-pentanediol 1mM TEW