8TEF
PorX primitive monoclinic crystal form
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.2 |
| Synchrotron site | ALS |
| Beamline | 5.0.2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-11-22 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9823 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 133.520, 57.517, 149.141 |
| Unit cell angles | 90.00, 98.39, 90.00 |
Refinement procedure
| Resolution | 45.400 - 2.850 |
| R-factor | 0.17896 |
| Rwork | 0.177 |
| R-free | 0.22159 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.238 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0411) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 46.000 | 46.000 | 2.900 |
| High resolution limit [Å] | 2.850 | 7.720 | 2.850 |
| Rmerge | 0.103 | 0.044 | 0.325 |
| Rmeas | 0.119 | 0.052 | 0.379 |
| Rpim | 0.058 | 0.026 | 0.191 |
| Total number of observations | 210610 | ||
| Number of reflections | 53000 | 2821 | 2594 |
| <I/σ(I)> | 7.7 | ||
| Completeness [%] | 100.0 | 100 | 100 |
| Redundancy | 4 | 3.7 | 3.8 |
| CC(1/2) | 0.984 | 0.995 | 0.891 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.1 | 293 | 0.2 M lithium sulfate, 0.1 M tris pH 8.1 and 35% polyethylene glycol 400 |