Tricomplex of RMC-7977, KRAS G12V, and CypA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]100
Detector technologyPIXEL
Collection date2021-12-13
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97946
Spacegroup nameP 21 21 21
Unit cell lengths65.560, 84.090, 127.100
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.580 - 1.570
R-factor0.1797
Rwork0.178
R-free0.21070
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle0.859
Data reduction softwareHKL-2000
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.5801.626
High resolution limit [Å]1.5701.570
Rmerge0.1062.779
Rmeas0.1152.967
Rpim0.0441.136
Number of reflections969079506
<I/σ(I)>10.670.93
Completeness [%]98.297.67
Redundancy6.66.9
CC(1/2)0.9980.359
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP729124% PEG6000, 0.1 M imidazole, pH 7