8T64
Apo Cam1(42-206)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-07-08 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9792 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 43.783, 120.551, 51.544 |
Unit cell angles | 90.00, 115.34, 90.00 |
Refinement procedure
Resolution | 46.590 - 2.250 |
R-factor | 0.2071 |
Rwork | 0.205 |
R-free | 0.24410 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.016 |
RMSD bond angle | 1.281 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.17.1_3660)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.330 |
High resolution limit [Å] | 2.250 | 2.250 |
Rmerge | 0.083 | |
Number of reflections | 96801 | 22371 |
<I/σ(I)> | 24.3 | |
Completeness [%] | 97.8 | |
Redundancy | 4.3 | |
CC(1/2) | 0.996 | 0.955 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.2 M sodium chloride, 0.1 M sodium cacodylate trihydrate, pH 6.6, 25% PEG3350 (w/v) |