Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8SZQ

Cat DHX9 bound to ADP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2021-04-17
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.95364
Spacegroup nameP 43 21 2
Unit cell lengths86.010, 86.010, 348.850
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.170 - 2.711
Rwork0.226
R-free0.27350
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.002
RMSD bond angle0.708
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0405)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.1702.830
High resolution limit [Å]2.7102.710
Rmerge0.1271.519
Rmeas0.1291.549
Rpim0.0250.299
Total number of observations959448110071
Number of reflections366934317
<I/σ(I)>23.12.9
Completeness [%]99.8
Redundancy26.125.5
CC(1/2)1.0000.791
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82910.15 M Ammonium sulfate, 0.1 M TRIS pH 8, 19% (w/v) PEG 4000; 5 mM ADP and 50 mM magnesium chloride in protein solution

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon