8SVI
Ubiquitin variant i53:Mutant L67H with 53BP1 Tudor domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-12-08 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.95372 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 40.380, 46.870, 89.730 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.210 - 1.150 |
Rwork | 0.205 |
R-free | 0.21980 |
Structure solution method | MOLECULAR REPLACEMENT |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0352) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.210 | 1.170 |
High resolution limit [Å] | 1.150 | 1.150 |
Rmerge | 0.986 | |
Rpim | 0.034 | |
Number of reflections | 59957 | 5255 |
<I/σ(I)> | 10.1 | 1.79 |
Completeness [%] | 98.0 | 86.9 |
Redundancy | 7 | |
CC(1/2) | 0.997 | 0.558 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 296 | 0.1 M MES pH 6.0, 0.2 M Trimethylamine N-oxide dehydrate, 11% w/v PEG MME 2000 |