8SUC
NHL-2 NHL domain
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-03-16 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 82.666, 82.666, 110.048 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 33.530 - 1.400 |
| R-factor | 0.1601 |
| Rwork | 0.160 |
| R-free | 0.17650 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.870 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 33.530 | 1.450 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Number of reflections | 75045 | 7400 |
| <I/σ(I)> | 22.13 | |
| Completeness [%] | 99.4 | |
| Redundancy | 9.4 | |
| CC(1/2) | 0.999 | 0.852 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277.15 | 0.1 mM Hepes, PEG 4000 |