8S4A
CdaA-B04 complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE MASSIF-3 |
Synchrotron site | ESRF |
Beamline | MASSIF-3 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-08-15 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.96770 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 41.700, 64.460, 128.690 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.540 - 2.230 |
R-factor | 0.2031 |
Rwork | 0.201 |
R-free | 0.24360 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.003 |
RMSD bond angle | 0.534 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 45.540 | 50.000 | 2.330 |
High resolution limit [Å] | 2.230 | 17.000 | 2.230 |
Rmerge | 0.129 | 0.035 | 1.486 |
Rmeas | 0.149 | 0.041 | 1.741 |
Number of reflections | 31425 | 64 | 3897 |
<I/σ(I)> | 8.04 | ||
Completeness [%] | 96.1 | ||
Redundancy | 3.9 | ||
CC(1/2) | 0.996 | 0.999 | 0.370 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 293 | 3.7 M NaCl, 0.1M Na-HEPES pH 8.5 and 3 % DMSO |