8RYS
Human IL-1beta, unliganded
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-10-15 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.999980 |
| Spacegroup name | P 43 |
| Unit cell lengths | 54.784, 54.784, 76.173 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 27.390 - 1.160 |
| R-factor | 0.2068 |
| Rwork | 0.206 |
| R-free | 0.22080 |
| Structure solution method | FOURIER SYNTHESIS |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.340 |
| Data reduction software | autoPROC (1.1.7) |
| Data scaling software | Aimless (0.7.9) |
| Phasing software | BUSTER (2.11.8) |
| Refinement software | BUSTER (2.11.8) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.476 | 1.180 |
| High resolution limit [Å] | 1.160 | 1.160 |
| Rmerge | 0.030 | 1.032 |
| Rmeas | 0.033 | 1.294 |
| Rpim | 0.013 | 0.762 |
| Number of reflections | 71960 | 2033 |
| <I/σ(I)> | 23.4 | 0.7 |
| Completeness [%] | 92.7 | 52.8 |
| Redundancy | 6 | 2.5 |
| CC(1/2) | 0.999 | 0.363 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 293 | 0.1M TRIS pH 8.5, 2.4M ammonium phosphate |