8RT1

BTV15 VP5 at pH 9.0

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]80
Detector technologyPIXEL
Collection date2015-12-15
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97918
Spacegroup nameP 1
Unit cell lengths91.399, 142.205, 142.151
Unit cell angles119.54, 96.09, 95.80
Refinement procedure
Resolution46.630 - 2.800
R-factor0.24089
Rwork0.240
R-free0.26083
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.677
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHENIX
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.6702.900
High resolution limit [Å]2.8002.800
Rmerge0.1200.670
Number of reflections29054915781
<I/σ(I)>11
Completeness [%]98.0
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2980.09M sodium formate, 6.6% PGA-LM, 0.1M Tris (pH 9.0)

224931

PDB entries from 2024-09-11