Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8RT0

BTV-15 VP5 pH 6.0

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]80
Detector technologyPIXEL
Collection date2015-12-16
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.96864
Spacegroup nameH 3
Unit cell lengths76.870, 76.870, 163.110
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution51.570 - 2.190
R-factor0.20069
Rwork0.199
R-free0.22908
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.868
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHENIX
Refinement softwareREFMAC (5.8.0425)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]51.8002.250
High resolution limit [Å]2.1902.190
Rmerge0.070
Number of reflections184791322
<I/σ(I)>13.6
Completeness [%]100.0
Redundancy9.9
CC(1/2)0.650
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2981M Sodium Chloride, 0.1M Tris, pH 6.0

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon