Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-04-30 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.7999 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 35.470, 57.060, 60.750 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.630 - 1.300 |
Rwork | 0.165 |
R-free | 0.19680 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.864 |
Data reduction software | autoPROC |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0419) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 41.590 | 1.060 |
High resolution limit [Å] | 1.000 | 1.000 |
Rmeas | 0.072 | 3.350 |
Number of reflections | 52360 | 20775 |
<I/σ(I)> | 7.92 | 0.4 |
Completeness [%] | 99.8 | 99.7 |
Redundancy | 3.42 | |
CC(1/2) | 0.998 | 0.175 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 60% "Tacsimate" pH 7.0 |