8RQV
Erk2 MAP kinase (T188A) AMP-PNP complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE MASSIF-1 |
| Synchrotron site | ESRF |
| Beamline | MASSIF-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-02-26 |
| Detector | DECTRIS PILATUS3 2M |
| Wavelength(s) | 0.9655 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 48.757, 70.279, 59.889 |
| Unit cell angles | 90.00, 109.39, 90.00 |
Refinement procedure
| Resolution | 44.070 - 2.190 |
| R-factor | 0.2197 |
| Rwork | 0.217 |
| R-free | 0.26801 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.663 |
| Data reduction software | MOSFLM |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.070 | 2.260 |
| High resolution limit [Å] | 2.190 | 2.190 |
| Number of reflections | 19524 | 1647 |
| <I/σ(I)> | 9.7 | |
| Completeness [%] | 98.9 | |
| Redundancy | 2.9 | |
| CC(1/2) | 0.972 | 0.402 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1M hepes pH=7, 4% v/v PEG 400 and 2M ammonium sulfate. |