Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

8R4M

CSP1 M48L mutant with Iodide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2017-04-29
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 42 21 2
Unit cell lengths87.744, 87.744, 50.150
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.872 - 1.950
Rwork0.179
R-free0.22970
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.511
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0266)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]43.90043.8702.000
High resolution limit [Å]1.9508.9401.950
Rmerge1.736
Rmeas1.872
Rpim0.695
Number of reflections148271981022
<I/σ(I)>12
Completeness [%]100.0
Redundancy13.310.113.5
CC(1/2)0.9991.0000.793
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.150.1 M Tris-Bicine pH 8.5 plus 12.5% v/v 2-methyl-2,4 pentanediol (racemic), 12.5% w/v PEG 1000, 12.5% w/v PEG 3350, 0.03 M sodium fluoride, 0.03 M sodium bromide and 0.03 M sodium iodide

238895

PDB entries from 2025-07-16

PDB statisticsPDBj update infoContact PDBjnumon