8QCI
FCGBP D10 Assembly Segment
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-06-22 |
| Detector | RIGAKU HyPix-3000 |
| Wavelength(s) | 1.34 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 43.716, 54.321, 129.106 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 19.490 - 2.200 |
| R-factor | 0.2005 |
| Rwork | 0.196 |
| R-free | 0.25650 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 0.897 |
| Data reduction software | CrysalisPro |
| Data scaling software | CrysalisPro |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.20_4459: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.490 | 2.280 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Rmerge | 0.165 | 0.897 |
| Rpim | 0.067 | 0.509 |
| Number of reflections | 16209 | 1567 |
| <I/σ(I)> | 10.9 | 2.3 |
| Completeness [%] | 99.6 | |
| Redundancy | 6.5 | |
| CC(1/2) | 0.988 | 0.599 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 50 mM Tris, pH 8.0, 22% w/v PEG 8,000, 20% v/v glycerol |