Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

8PRU

Engineered form of T thermophiles AHIR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2012-12-14
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 21 21 2
Unit cell lengths136.030, 142.720, 126.130
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution63.060 - 2.000
Rwork0.259
R-free0.28840
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.449
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0411)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]63.0601.920
High resolution limit [Å]1.8901.890
Rmerge0.1541.122
Rmeas0.1771.298
Rpim0.0850.637
Number of reflections1846969269
<I/σ(I)>5.61.5
Completeness [%]94.796.8
Redundancy43.9
CC(1/2)0.9930.679
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP294PEG 4000

246031

PDB entries from 2025-12-10