8JKR

SP1746 in complex with UMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL19U1
Synchrotron siteSSRF
BeamlineBL19U1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-01-26
DetectorDECTRIS PILATUS 200K
Wavelength(s)0.97852
Spacegroup nameP 32 2 1
Unit cell lengths69.884, 69.884, 87.967
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.663 - 2.000
R-factor0.19279
Rwork0.191
R-free0.22526
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.352
Data reduction softwareHKL-2000
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0102.050
High resolution limit [Å]2.0002.000
Number of reflections172611266
<I/σ(I)>24.9
Completeness [%]99.9
Redundancy9.6
CC(1/2)0.9990.979
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP287.1525% PEG4000, 0.15 M (NH4)2SO4, 0.1 M MES, pH 5.5