8J9S
leucine zipper complex of AIMP1 and AIMP2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2021-06-28 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97957 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 95.445, 95.445, 74.399 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.660 - 3.010 |
R-factor | 0.2366 |
Rwork | 0.232 |
R-free | 0.27310 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.473 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.050 |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 7226 | 346 |
<I/σ(I)> | 19.8 | |
Completeness [%] | 99.9 | |
Redundancy | 13.5 | |
CC(1/2) | 1.000 | 0.785 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.2 | 294 | 62% MPD |