8ISM
HSA-Pt compound complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-04-22 |
| Detector | DECTRIS EIGER2 S 9M |
| Wavelength(s) | 0.987 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 187.413, 38.573, 95.990 |
| Unit cell angles | 90.00, 105.11, 90.00 |
Refinement procedure
| Resolution | 92.670 - 2.760 |
| R-factor | 0.22747 |
| Rwork | 0.223 |
| R-free | 0.31221 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.783 |
| Data reduction software | HKL-3000 |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 92.670 | 3.920 | 2.760 |
| High resolution limit [Å] | 1.300 | 3.890 | 2.250 |
| Rmerge | 0.050 | 0.131 | 0.152 |
| Rmeas | 0.249 | 0.145 | 0.168 |
| Number of reflections | 108443 | 6362 | 12235 |
| <I/σ(I)> | 1.38 | ||
| Completeness [%] | 99.6 | ||
| Redundancy | 3.6 | ||
| CC(1/2) | 0.980 | 0.976 | 0.571 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG3350, 50 mM potassium phosphate (pH 7.5), 5% glycerol, 4% DMSO |