8I0E
Sb3GT1 complex with UDP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-01-12 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 101.650, 61.280, 68.640 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.750 - 1.900 |
| R-factor | 0.20183 |
| Rwork | 0.200 |
| R-free | 0.23891 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.413 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1-4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 45.710 | 1.940 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 34695 | 1706 |
| <I/σ(I)> | 18.6 | |
| Completeness [%] | 99.0 | |
| Redundancy | 13 | |
| CC(1/2) | 0.990 | 0.750 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.2M Sodium malonate pH 4.0, 20% PEG 3,350. |