8HMG
The open state of RGLG2-VWA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AichiSR BEAMLINE BL2S1 |
Synchrotron site | AichiSR |
Beamline | BL2S1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-05-02 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9789 |
Spacegroup name | P 31 |
Unit cell lengths | 244.410, 244.410, 63.650 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 49.810 - 2.810 |
R-factor | 0.18468 |
Rwork | 0.183 |
R-free | 0.20816 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.479 |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.810 | 2.860 |
High resolution limit [Å] | 2.810 | 2.810 |
Number of reflections | 103535 | 5094 |
<I/σ(I)> | 11 | |
Completeness [%] | 99.9 | |
Redundancy | 10.43 | |
CC(1/2) | 0.996 | 0.734 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 289 | 100 mM Tris-HCl, pH 7.5, 200 mM ammonium sulfate, 20% polyethylene glycol 4000 |