Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

8GMM

Stenotrophomonas maltophilia Holo HphA

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-05
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9795
Spacegroup nameP 1 21 1
Unit cell lengths46.618, 76.663, 62.264
Unit cell angles90.00, 94.33, 90.00
Refinement procedure
Resolution48.250 - 1.800
R-factor0.153
Rwork0.152
R-free0.17850
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.906
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.2501.864
High resolution limit [Å]1.8001.800
Number of reflections356311470
<I/σ(I)>13.86
Completeness [%]82.3
Redundancy5.2
CC(1/2)0.9970.829
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1 M Tris-HCL pH8.5, 25% (w/v) PEG3350

237735