8G3T
MBP-Mcl1 in complex with ligand 12
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-04-02 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.9999 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 99.309, 137.340, 38.572 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 80.470 - 1.830 |
R-factor | 0.18999 |
Rwork | 0.188 |
R-free | 0.23321 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.467 |
Data reduction software | autoPROC (Jan 26, 2018) |
Data scaling software | autoPROC (Jan 26, 2018) |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 80.470 | 1.996 |
High resolution limit [Å] | 1.830 | 1.830 |
Rmeas | 0.136 | 1.440 |
Rpim | 0.048 | 0.530 |
Number of reflections | 38116 | 1907 |
<I/σ(I)> | 13.4 | 1.8 |
Completeness [%] | 92.2 | |
Redundancy | 7.8 | |
CC(1/2) | 0.990 | 0.740 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.5 | 285 | 0.17M Mg Formate, 23.5% (w/v) PEG3350 |