8FVO
PCSK9 in complex with an inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2013-10-17 |
| Detector | DECTRIS EIGER R 1M |
| Wavelength(s) | 1 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 62.830, 70.235, 149.422 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.086 - 2.652 |
| R-factor | 0.1862 |
| Rwork | 0.183 |
| R-free | 0.23870 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.013 |
| RMSD bond angle | 1.603 |
| Data reduction software | HKL-2000 |
| Data scaling software | Aimless |
| Phasing software | FFT |
| Refinement software | PHENIX (1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 149.422 | 2.661 |
| High resolution limit [Å] | 2.652 | 2.652 |
| Rmerge | 0.154 | 1.112 |
| Number of reflections | 19859 | 209 |
| <I/σ(I)> | 11.3 | |
| Completeness [%] | 100.0 | |
| Redundancy | 6.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 20.0% Peg-6000, 0.1M Tris pH8.0 |