8FRV
LSD1-CoREST in complex with T17, short soaking
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID30B |
| Synchrotron site | ESRF |
| Beamline | ID30B |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-02-22 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.96770 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 118.681, 178.655, 235.702 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.340 - 2.720 |
| R-factor | 0.2196 |
| Rwork | 0.219 |
| R-free | 0.24790 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.438 |
| Data reduction software | xia2 |
| Data scaling software | xia2 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 59.340 | 2.770 |
| High resolution limit [Å] | 2.720 | 2.720 |
| Number of reflections | 67413 | 6660 |
| <I/σ(I)> | 9.6 | |
| Completeness [%] | 100.0 | |
| Redundancy | 13.9 | 14.5 |
| CC(1/2) | 0.997 | 0.311 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |