8FK2
The N-terminal VicR from Streptococcus mutans
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-03-16 |
| Detector | RAYONIX MX300-HS |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 65 |
| Unit cell lengths | 53.032, 53.032, 196.290 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 41.600 - 2.290 |
| R-factor | 0.2049 |
| Rwork | 0.199 |
| R-free | 0.25900 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.082 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX (1.20.1_4487) |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.600 | 2.370 |
| High resolution limit [Å] | 2.290 | 2.290 |
| Rmerge | 0.112 | 0.320 |
| Number of reflections | 12917 | 1189 |
| <I/σ(I)> | 26.736 | |
| Completeness [%] | 92.4 | |
| Redundancy | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1M HEPES pH 7.0, 20% PEG 3350, 0.1M Sodium chloride |