Lysozyme Anomalous Dataset at 293 K and 12 keV

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL14-1
Synchrotron siteSSRL
BeamlineBL14-1
Temperature [K]293
Detector technologyPIXEL
Collection date2020-01-19
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0332
Spacegroup nameP 43 21 2
Unit cell lengths77.794, 77.794, 37.127
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution33.529 - 1.200
Rwork0.121
R-free0.14620
Structure solution methodSAD
RMSD bond length0.010
RMSD bond angle1.801
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareSHELXDE
Refinement softwareREFMAC (5.8.0352)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.0601.220
High resolution limit [Å]1.2001.200
Rmerge0.0925.750
Rpim0.0130.790
Number of reflections341931567
<I/σ(I)>27.91.6
Completeness [%]95.090.1
Redundancy53.952.8
CC(1/2)1.0000.622
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.52985 uL of 0.6 M Sodium Chloride in 100 mM Sodium Acetate buffer pH 4.5 and 25% ethylene glycol were mixed with 5 uL 100 mg/mL lysozyme in 100 mM Sodium Acetate

219869