Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8E8K

Human DNA polymerase eta-DNA-rC-ended primer-dGMPNPP ternary mismatch complex with Mg2+

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]100
Detector technologyCCD
Collection date2022-02-08
DetectorRAYONIX MX-300
Wavelength(s)0.978720
Spacegroup nameP 61
Unit cell lengths98.077, 98.077, 81.890
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution42.470 - 2.400
R-factor0.1849
Rwork0.182
R-free0.23720
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7m7l
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]42.47042.4702.520
High resolution limit [Å]2.3807.0702.380
Rmerge0.0570.0300.320
Rmeas0.0600.0310.345
Total number of observations368412
Number of reflections3490613455246
<I/σ(I)>28.4365.155.12
Completeness [%]98.799.691.8
Redundancy10.55410.9766.973
CC(1/2)0.9991.0000.945
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7298PEG 2000MME, 0.1 M MES

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon