8CN7
Pa.FabF-C164Q in complex with platencin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-2 |
Synchrotron site | ESRF |
Beamline | ID23-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-11-26 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.976250 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 71.001, 64.779, 84.586 |
Unit cell angles | 90.00, 106.30, 90.00 |
Refinement procedure
Resolution | 50.690 - 2.100 |
R-factor | 0.17343 |
Rwork | 0.171 |
R-free | 0.22445 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.480 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 64.780 | 2.160 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmerge | 0.071 | 0.422 |
Number of reflections | 42000 | 3512 |
<I/σ(I)> | 9.5 | 2.2 |
Completeness [%] | 97.3 | 99.4 |
Redundancy | 2.9 | 3 |
CC(1/2) | 0.996 | 0.724 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 298 | 0.20M ammonium formate and 31.2% PEG3350 |