8CHD
NtUGT1 in two conformations
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.2 |
| Synchrotron site | ALS |
| Beamline | 8.2.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-06-19 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 52.310, 86.850, 100.980 |
| Unit cell angles | 90.00, 93.17, 90.00 |
Refinement procedure
| Resolution | 50.410 - 2.340 |
| R-factor | 0.1912 |
| Rwork | 0.189 |
| R-free | 0.23450 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.726 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.410 | 2.420 |
| High resolution limit [Å] | 2.340 | 2.340 |
| Number of reflections | 37833 | 3374 |
| <I/σ(I)> | 10.02 | 1.23 |
| Completeness [%] | 98.6 | 88.34 |
| Redundancy | 3.7 | 3.2 |
| CC(1/2) | 0.995 | 0.430 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 295 | 0.2 M magnesium chloride 25% PEG 3350 0.1 M HEPES |