8C40
14-3-3sigma bound to PKA-responsive ERa phosphopeptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, DESY BEAMLINE P11 |
| Synchrotron site | PETRA III, DESY |
| Beamline | P11 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-04-06 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.0332 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 82.141, 111.980, 62.806 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.570 - 1.400 |
| R-factor | 0.1662 |
| Rwork | 0.165 |
| R-free | 0.18420 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.907 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.20.1-4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 45.570 | 1.420 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Number of reflections | 56896 | 2719 |
| <I/σ(I)> | 24.9 | 4.5 |
| Completeness [%] | 99.6 | |
| Redundancy | 13.3 | |
| CC(1/2) | 0.999 | 0.930 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M Hepes pH 7.1, 0.19 M CaCl2, 25% PEG400, 5% glycerol |