Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8C3I

Dark state of PAS-GAF fragment from Deinococcus radiodurans phytochrome

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeFREE ELECTRON LASER
Source detailsSACLA BEAMLINE BL3
Synchrotron siteSACLA
BeamlineBL3
Temperature [K]298
Detector technologyCCD
Collection date2021-06-24
DetectorMPCCD
Wavelength(s)1.7712
Spacegroup nameP 21 21 21
Unit cell lengths54.950, 116.500, 117.700
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution33.070 - 2.100
R-factor0.1626
Rwork0.161
R-free0.19620
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6t3l
RMSD bond length0.008
RMSD bond angle1.084
Data reduction softwareCrystFEL
Data scaling softwareCrystFEL
Phasing softwarePHASER
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.07010.300
High resolution limit [Å]2.1002.100
Number of reflections500861821
<I/σ(I)>10
Completeness [%]100.0100
Redundancy18
CC(1/2)0.9800.610
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE4.9529860 mM Sodium Acetate, 3.3% PEG400, 1 mM DTT, 30% 2-methyl-2,4-pentanediol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon